ICNIRP. Guidelines on limits of exposure to static magnetic fields. Health Physics, Vol.66, N.1, January 1994, pp.100-106.

Download PDF:        [INT] [EXT]

Full name  
ICNIRP Guidelines 1994 - Exposure limits for static magnetic fields

ICNIRP. Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz). Health Physics, Vol.74, N.4, April 1998, pp.494-522.

Download PDF:        [INT] [EXT]

Full name  
ICNIRP Guidelines 1998 - Current density - Limits for workers - Stimulation effects - Basic restrictions
ICNIRP 1998 Guidelines - Average SAR over the whole body - Limits for workers - Thermal effects - Basic restrictions
ICNIRP 1998 Guidelines - SAR in the head and trunk - Limits for workers - Thermal effects - Basic restrictions
ICNIRP Guidelines 1998 - SAR in limbs - Limits for workers - Thermal effects - Basic restrictions
ICNIRP Guidelines 1998 - Power density - Limits for workers - Thermal effects - Basic restrictions
ICNIRP Guidelines 1998 - Specific absorption - Limits for workers - Thermal effects - Basic restrictions
ICNIRP Guidelines 1998 - Current density - Limits for the general public - Stimulation effects - Basic restrictions
ICNIRP Guidelines 1998 - Average SAR over the whole body - Limits for the general public - Thermal effects - Basic restrictions
ICNIRP Guidelines 1998 - SAR in the head and trunk - Limits for the general public - Thermal effects - Basic restrictions
ICNIRP 1998 Guidelines - SAR in limbs - Limits for the general public - Thermal effects - Basic restrictions
ICNIRP 1998 Guidelines - Power density - Limits for the general public - Thermal effects - Basic restrictions
ICNIRP Guidelines 1998 - Specific absorption - Limits for the general public - Thermal effects - Basic restrictions
ICNIRP Guidelines 1998 - Electric field - Limits for workers - Stimulation effects - Reference levels
ICNIRP Guidelines 1998 - Electric field - Limits for workers - Thermal effects - Reference levels
ICNIRP Guidelines 1998 - Electric field - Limits for workers - Peak reference levels
ICNIRP Guidelines 1998 - Electric field - Limits for the general public - Stimulation effects - Reference levels
ICNIRP Guidelines 1998 - Electric field - Limits for the general public - Thermal effects - Reference levels
ICNIRP 1998 Guidelines - Electric field - Limits for the general public - Peak reference levels
ICNIRP Guidelines 1998 - Magnetic induction - Limits for workers - Stimulation effects - Reference levels
ICNIRP Guidelines 1998 - Magnetic induction - Limits for workers - Thermal effects - Reference levels
ICNIRP Guidelines 1998 - Magnetic induction - Limits for workers - Peak reference levels
ICNIRP Guidelines 1998 - Magnetic induction - Limits for the general public - Stimulation effects - Reference levels
ICNIRP Guidelines 1998 - Magnetic induction - Limits for the general public - Thermal effects - Reference levels
ICNIRP Guidelines 1998 - Magnetic induction - Limits for the general public - Peak reference levels
ICNIRP Guidelines 1998 - Power density - Limits for workers - Thermal effects - Reference levels
ICNIRP Guidelines 1998 - Power density - Limits for workers - Peak reference levels
ICNIRP 1998 Guidelines - Power density - Limits for the general public - Thermal effects - Reference levels
ICNIRP Guidelines 1998 - Power density - Limits for the general public - Peak reference levels
ICNIRP Guidelines 1998 - Contact current - Limits for workers - Stimulation effects - Reference levels
ICNIRP Guidelines 1998 - Contact current - Limits for the general public - Stimulation effects - Reference levels
ICNIRP Guidelines 1998 - Induced current in each limb - Limits for workers - Thermal effects - Reference levels
ICNIRP Guidelines 1998 - Induced current in each limb - Limits for the general public - Thermal effects - Reference levels

ICNIRP. Guidelines on limits of exposure to static magnetic fields. Health Physics, Vol.96, N.4, April 2009, pp.504-514.

Download PDF:        [INT] [EXT]

Full name  
ICNIRP Guidelines 2009 - Exposure limits for static magnetic fields

ICNIRP. Guidelines for limiting exposure to time-varying electric and magnetic fields (1 Hz to 100 kHz). Health Physics, Vol.99, N.6, December 2010, pp.818-836.

Download PDF:        [INT] [EXT]

Full name  
ICNIRP Guidelines 2010 - Internal electric field in the central nervous system tissues of the head - Limits for workers - Stimulation effects - Basic restrictions
ICNIRP Guidelines 2010 - Internal electric field in all tissues of the head and body - Limits for workers - Stimulation effects - Basic restrictions
ICNIRP 2010 Guidelines - Internal electric field in the central nervous system tissues of the head - Limits for the general public - Stimulation effects - Basic restrictions
ICNIRP Guidelines 2010 - Internal electric field in all tissues of the head and body - Limits for the general public - Stimulation effects - Basic restrictions
ICNIRP Guidelines 2010 - Electric field - Limits for workers - Stimulation effects - Reference levels
ICNIRP Guidelines 2010 - Electric field - Limits for the general public - Stimulation effects - Reference levels
ICNIRP Guidelines 2010 - Magnetic induction - Limits for workers - Stimulation effects - Reference levels
ICNIRP Guidelines 2010 - Magnetic induction - Limits for the general public - Stimulation effects - Reference levels
ICNIRP Guidelines 2010 - Contact current - Limits for workers - Stimulation effects - Reference levels
ICNIRP Guidelines 2010 - Contact current - Limits for the general public - Stimulation effects - Reference levels

ICNIRP. Guidelines for limiting exposure to electric fields induced by movement of the human body in a static magnetic field and by time-varying magnetic fields below 1 Hz. Health Physics, Vol.106, N.3, March 2014, pp.418‐425.

Download PDF:        [INT] [EXT]

Full name  
ICNIRP Guidelines 2014 - Variation in magnetic induction over 3s - Effects of nausea or dizziness - Basic restrictions under uncontrolled conditions
ICNIRP Guidelines 2014 - Peak-to-peak magnetic induction - Effects of nausea or dizziness - Basic restrictions under uncontrolled conditions
ICNIRP Guidelines 2014 - Internal electric field in the central nervous system tissues of the head - Stimulation effects (phosphenes) - Basic restrictions under uncontrolled conditions
ICNIRP Guidelines 2014 - Internal electric field in all tissues of the head and body - Stimulation effects (PNS) - Basic restrictions under controlled conditions
ICNIRP Guidelines 2014 - Time derivative of magnetic induction - Stimulation effects (phosphenes) - Reference levels in uncontrolled conditions
ICNIRP Guidelines 2014 - Time derivative of magnetic induction - Stimulation effects (PNS) - Reference levels under controlled conditions

Raccomandazione 1999/519/CE del Consiglio europeo del 12 luglio 1999 relativa alla limitazione dell'esposizione della popolazione ai campi elettromagnetici da 0 Hz a 300 GHz. Gazzetta ufficiale delle Comunità europee L 199/59-70, 30.7.1999.

Download PDF:        [INT] [EXT]

Full name  
Recommendation 1999/519/EC - Current density - Stimulation effects - Basic restrictions
Recommendation 1999/519/EC - Average SAR over the whole body - Thermal effects - Basic restrictions
Recommendation 1999/519/EC - SAR in the head and trunk - Thermal effects - Basic restrictions
Recommendation 1999/519/EC - SAR in the limbs - Thermal effects - Basic restrictions
Recommendation 1999/519/EC - Power density - Thermal effects - Basic restrictions
Recommendation 1999/519/EC - Specific absorption - Thermal effects - Basic restrictions
Recommendation 1999/519/EC - Electric field - Stimulation effects - Reference levels
Recommendation 1999/519/EC - Electric field - Thermal effects - Reference levels
Recommendation 1999/519/EC - Electric field - Peak reference levels
Recommendation 1999/519/EC - Magnetic induction - Stimulation effects - Reference levels
Recommendation 1999/519/EC - Magnetic induction - Thermal effects - Reference levels
Recommendation 1999/519/EC - Magnetic induction - Peak reference levels
Recommendation 1999/519/EC - Power density - Thermal effects - Reference levels
Recommendation 1999/519/EC - Power density - Peak reference levels
Recommendation 1999/519/EC - Contact current - Stimulation effects - Reference levels
Recommendation 1999/519/EC - Induced current in each limb - Thermal effects - Reference levels
Recommendation 1999/519/EC - Exposure limits for static magnetic fields

Direttiva 2013/35/UE del Parlamento Europeo e del Consiglio del 26 giugno 2013 sulle disposizioni minime di sicurezza e di salute relative all’esposizione dei lavoratori ai rischi derivanti dagli agenti fisici (campi elettromagnetici). Gazzetta ufficiale dell'Unione europea L 179/1-21, 29.6.2013.

Download PDF:        [INT] [EXT]

Full name  
Directive 2013/35/EU - Internal electric field in the tissues of the central nervous system of the head - Stimulation effects - Exposure limit values
Directive 2013/35/EU - Internal electric field in all tissues of the head and body - Stimulation effects - Exposure limit values
Directive 2013/35/EU - Average SAR for the whole body - Thermal effects - Exposure limit values
Directive 2013/35/EU - SAR in the head and trunk - Thermal effects - Exposure limit values
Directive 2013/35/EU - SAR in the limbs - Thermal effects - Exposure limit values
Directive 2013/35/EU - Power density - Thermal effects - Exposure limit values
Directive 2013/35/EU - Specific absorption - Thermal effects - Exposure limit values
Directive 2013/35/EU - Electric field - Non-thermal effects - Lower action values
Directive 2013/35/EU - Electric field - Non-thermal effects - Upper action values
Directive 2013/35/EU - Electric field - Thermal effects - Action values
Directive 2013/35/EU - Magnetic induction - Non-thermal effects - Lower action values
Directive 2013/35/EU - Magnetic induction - Non-thermal effects - Upper action values
Directive 2013/35/EU - Magnetic induction - Non-thermal effects - Action values for exposure of limbs to localized fields
Directive 2013/35/EU - Magnetic induction - Thermal effects - Action values
Directive 2013/35/EU - Power density - Thermal effects - Action values
Directive 2013/35/EU - Power density - Peak action values
Directive 2013/35/EU - Contact current - Non-thermal effects - Action values
Directive 2013/35/EU - Contact current - Thermal effects - Action values
Directive 2013/35/EU - Induced current in each limb - Thermal effects - Action values
Directive 2013/35/EU - Exposure limits for static magnetic fields

ICNIRP. Guidelines for limiting exposure to electric fields induced by movement of the human body in a static magnetic field and by time-varying magnetic fields below 1 Hz. Health Physics, Vol.106, N.3, March 2014, pp.418‐425.
+
Direttiva 2013/35/UE del Parlamento Europeo e del Consiglio del 26 giugno 2013 sulle disposizioni minime di sicurezza e di salute relative all’esposizione dei lavoratori ai rischi derivanti dagli agenti fisici (campi elettromagnetici). Gazzetta ufficiale dell'Unione europea L 179/1-21, 29.6.2013.

Download PDF:        [INT]

Full name  
ICNIRP Guidelines 2014 + Directive 2013/35/EU - Internal electric field in the tissues of the central nervous system of the head - Stimulation effects (phosphenes) - Sensory exposure limit values/Basic restrictions under uncontrolled conditions
ICNIRP Guidelines 2014 + Directive 2013/35/EU - Internal electric field in all tissues of the head and body - Stimulation effects (PNS) - Health exposure limit values/Basic restrictions under controlled conditions
ICNIRP Guidelines 2014 + Directive 2013/35/EU - Magnetic induction - Stimulation effects (phosphenes) - Lower action values/Reference levels under uncontrolled conditions
ICNIRP Guidelines 2014 + Directive 2013/35/EU - Magnetic induction - Stimulation effects (PNS) - Upper action values/Reference levels in controlled conditions
Directive 2013/35/EU extended to 0Hz - Magnetic induction - Non-thermal effects - Action values for exposure of limbs to localized fields

ICNIRP. Guidelines for limiting exposure to electromagnetic fields (100 kHz to 300 GHz). Health Phys 118(00):000–000; 2020. Pre-print. DOI: 10.1097/HP.0000000000001210.

Download PDF:        [INT] [EXT]

Full name  
ICNIRP 2020 Guidelines - Average SAR over the whole body - Limits for workers - Thermal effects - Basic restrictions
ICNIRP Guidelines 2020 - SAR in the head and trunk - Limits for workers - Thermal effects - Basic restrictions
ICNIRP Guidelines 2020 - SAR in the limbs - Limits for workers - Thermal effects - Basic restrictions
ICNIRP Guidelines 2020 - Power density - Limits for workers - Thermal effects - Basic restrictions
ICNIRP 2020 Guidelines - Specific absorption in the head and trunk - Limits for workers - Thermal effects - Basic restrictions
ICNIRP Guidelines 2020 - Specific absorption in limbs - Limits for workers - Thermal effects - Basic restrictions
ICNIRP Guidelines 2020 - Energy density - Limits for workers - Thermal effects - Basic restrictions
ICNIRP Guidelines 2020 - Peak electric field - Limits for workers - Thermal effects - Basic restrictions
ICNIRP Guidelines 2020 - Average SAR for the whole body - Limits for the general public - Thermal effects - Basic restrictions
ICNIRP Guidelines 2020 - SAR in the head and trunk - Limits for the general public - Thermal effects - Basic restrictions
ICNIRP Guidelines 2020 - SAR in limbs - Limits for the general public - Thermal effects - Basic restrictions
ICNIRP Guidelines 2020 - Power density - Limits for the general public - Thermal effects - Basic restrictions
ICNIRP 2020 Guidelines - Specific absorption in the head and trunk - Limits for the general public - Thermal effects - Basic restrictions
ICNIRP 2020 Guidelines - Specific absorption in limbs - Limits for the general public - Thermal effects - Basic restrictions
ICNIRP Guidelines 2020 - Energy density - Limits for the general public - Thermal effects - Basic restrictions
ICNIRP 2020 Guidelines - Peak electric field - Limits for the general public - Thermal effects - Basic restrictions
ICNIRP Guidelines 2020 - Average electric field over 30 minutes - Limits for workers - Thermal effects - Reference levels
ICNIRP Guidelines 2020 - Average electric field over 6 minutes - Limits for workers - Thermal effects - Reference levels
ICNIRP Guidelines 2020 - Peak electric field - Limits for workers - Thermal effects - Reference levels
ICNIRP Guidelines 2020 - Average electric field over 30 minutes - Limits for the general public - Thermal effects - Reference levels
ICNIRP 2020 Guidelines - Average electric field over 6 minutes - Limits for the general public - Thermal effects - Reference levels
ICNIRP Guidelines 2020 - Peak electric field - Limits for the general public - Thermal effects - Reference levels
ICNIRP 2020 Guidelines - Average magnetic induction over 30 minutes - Limits for workers - Thermal effects - Reference levels
ICNIRP 2020 Guidelines - Average magnetic induction over 6 minutes - Limits for workers - Thermal effects - Reference levels
ICNIRP Guidelines 2020 - Peak magnetic induction - Limits for workers - Thermal effects - Reference levels
ICNIRP 2020 Guidelines - Average magnetic induction over 30 minutes - Limits for the general public - Thermal effects - Reference levels
ICNIRP Guidelines 2020 - Average magnetic induction over 6 minutes - Limits for the general public - Thermal effects - Reference levels
ICNIRP Guidelines 2020 - Peak magnetic induction - Limits for the general public - Thermal effects - Reference levels
ICNIRP Guidelines 2020 - Average power density over 30 minutes - Limits for workers - Thermal effects - Reference levels
ICNIRP 2020 Guidelines - Average power density over 6 minutes - Limits for workers - Thermal effects - Reference levels
ICNIRP Guidelines 2020 - Average power density over 30 minutes - Limits for the general public - Thermal effects - Reference levels
ICNIRP Guidelines 2020 - Average power density over 6 minutes - Limits for the general public - Thermal effects - Reference levels
ICNIRP Guidelines 2020 - Energy density - Limits for workers - Thermal effects - Reference levels
ICNIRP 2020 Guidelines - Energy density - Limits for the general public - Thermal effects - Reference levels
ICNIRP Guidelines 2020 - Induced current in each limb - Limits for workers - Thermal effects - Reference levels
ICNIRP Guidelines 2020 - Induced current in each limb - Limits for the general public - Thermal effects - Reference levels
Functions selection
Abbreviations and acronyms in function names
  • Stim: stimulation effects
  • Term: thermal effects
  • Occ: occupational limit
  • Pop: population limit
  • Picco: Peak
  • LR: Reference Limit
  • VLE: Exposure Limit Value
  • VA: Attention Value
  • VA Limbs: Attention Value referred to limbs
  • VA Inf: Lower Attention Value
  • VA Sup: Upper Attention Value
  • RB: Basic Restriction
  • Contr: Controlled conditions
  • Non Contr: Uncontrolled conditions
  • Eint: Internal electric field
  • Sens: Sensory (uncontrolled exposures)
  • Sanit: Healthcare (controlled exposures)
  • TesTro: Head and trunk
  • PWL: PieceWise Linear weight function
  • RCF: RC Filter weight function
Parameters and plot building
Undefined
Undefined

'List of standards' tab

This tab collects the standards of interest, grouped by publication (ICNIRP Guidelines, EC Recommendation, EU Directive). For each specific standard, the reference physical quantity, type of limit, effect and reference level are highlighted. Clicking on the 'Details' button opens a specific tab, in which:

  1. if the limits have a single value, they are shown in a table;
  2. if the limits depend on the frequency, they are displayed in a graph, the user can perform the calculation for a specific frequency and export the graph in PNG format.

'Norm comparison' tab

All the regulations appear in a multiple choice menu, grouped according to the physical quantity to which they refer. To view them, double-click on the name of the function, or make a multiple selection and press 'Append'. All the selected regulations are listed in the table that appears following these operations.

In this, for each function the following is indicated:

  1. Name of the function (next to which there is a cross-shaped icon to click to delete it from the list);
  2. Mode (PWL or RCF);
  3. Minimum frequency;
  4. Maximum frequency;
  5. Physical quantity (electric field, magnetic flux density, time derivative of flux density, power density).

The order in which the series relating to each regulation appear in the graph is the one shown in this table, from bottom to top. It can be changed by dragging with the mouse and appropriately reordering the rows of the table.

At this point you can proceed to create the graph by clicking on 'Graph'.

In the graph, you can disable the graphs relating to the individual regulations by clicking on the relative entries in the legend. This is also draggable, using the upper part as a handle (next to the icon with four arrows). This is a useful option both when viewing and when exporting the graph in PNG format (by clicking on the button that appears above the graph).

'Norm filter' tab

This tab allows you to filter the regulations displayed in Norm list and in Norm comparison. The parameters for which you can set a filter are:

  1. Type:
    • Basic restrictions or exposure limit values (ELVs)
    • Exposure limits
    • Reference levels, action values (AV), action levels (AL)
  2. Quantity:
    • Magnetic flux density
    • Time derivative of magnetic flux density (dB/dt)
    • Perceived change in magnetic flux density
    • Electric field
    • Current
    • Induced current density
    • Power density
    • Specific (energy) Absorption
    • Specific (energy) Absorption Rate
    • Energy density
  3. Metric:
    • Peak value
    • Peak-to-peak
    • Redempty value
    • Static field or DC value
  4. Subject:
    • Population and workers
    • Occupational exposures
    • Population exposures
  5. Effect:
    • Undifferentiated
    • Stimulatory effects
    • Thermal effects
    • Effects of nausea and dizziness in the static field
  6. Level:
    • Health (controlled exposures)
    • Undifferentiated
    • Sensory (uncontrolled exposures)
  7. Localization:
    • Localized exposure of the head
    • Localized exposure of the head and trunk
    • Localized exposure of the limbs
    • Generic localized exposure
    • Whole body exposure
  8. Dependency:
    • Constant limit.
    • The limit depends on both the frequency of the field and the duration of exposure.
    • The limit depends only on the frequency of the field.
    • The limit depends only on the duration of exposure.
  9. Minimum frequency
  10. Maximum frequency

Once the filter has been applied, only the standards corresponding to the set parameters will be displayed in the first two tabs.

Keywords: Limits, REgulation, Electromagnetic fields